Purpose

This study aims to evaluate the impact of the EpiFaith® syringe on the learning curve of anesthesia residents for the labor epidural technique. Anesthesia residents with prior experience placing < 5 labor epidurals will be enrolled. Their performance of 20 sequential labor epidural placements with either standard technique with a beveled glass syringe or the EpiFaith® syringe will be observed. Successful epidural placement over time with sequential epidural placement attempts will be measured between groups. The primary outcome will be rate of successful epidural placement. Success will be defined as a composite of 4 criteria: maximum 3 attempts for placement; no need to re-site at a different level; no required intervention by the supervising attending anesthesiologist; and adequate analgesia with a visual analog score (VAS) <3 at 30 minutes. We hypothesize that use of the EpiFaith® syringe will enable a faster learning curve for successful epidural placement. A cumulative sum chart (CUSUM) analysis will evaluate whether the EpiFaith® syringe causes deviation from the control learning curve. Secondary outcomes will include rate of inadvertent dural puncture and epidural replacement rate.

Conditions

Eligibility

Eligible Ages
Over 18 Years
Eligible Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • Anesthesiology residents with fewer than 5 prior epidural placement experiences

Exclusion Criteria

  • anesthesiology residents with more than 5 prior epidural placement experiences

Study Design

Phase
N/A
Study Type
Interventional
Allocation
Non-Randomized
Intervention Model
Factorial Assignment
Intervention Model Description
The study will be conducted as a quasi-eperimental trial. Study subjects will be assigned to one of the two groups for their epidural placement based on the month of their rotation, with alternating months: 1) EpiFaith® Group, in which EpiFaith® syringe is used; or 2) Control Group in which a conventional glass syringe is used
Primary Purpose
Supportive Care
Masking
None (Open Label)

Arm Groups

ArmDescriptionAssigned Intervention
Experimental
Control (glass epidural syringe)
  • Device: Control (glass) syringe
    glass epidural syringe
Experimental
EpiFaith syringe
  • Device: EpiFaith epidural syringe
    The EpiFaith syringe is an FDA-cleared epidural syringe.

Recruiting Locations

Brigham and Women's Hospital
Boston, Massachusetts 02115
Contact:
Michaela K Farber, MD MS
617-759-1609
mfarber@bwh.harvard.edu

More Details

Status
Recruiting
Sponsor
Brigham and Women's Hospital

Study Contact

Michaela K Farber, MD MS
617-759-1609
mfarber@bwh.harvard.edu

Detailed Description

The lumbar epidural technique for labor analgesia requires technical training and a manual skillset. A prior study evaluating anesthesia resident learning curves for a traditional labor epidural technique demonstrated a steep learning curve for the first 20 epidural placements, followed by a plateau with gradual proficiency maximized after 60 epidural placements (1). A prior study evaluated a spring-loaded epidural syringe among experienced providers (2). However, the impact of a spring-loaded epidural syringe on novice anesthesia resident learning curves is unknown. In addition, the impact of EpiFaith® use at the time of manual skill acquisition on success with subsequent traditional epidural technical skills is unknown. The EpiFaith® syringe is FDA-cleared and has a spring-loaded piston designed to detect entry into the epidural space upon loss of resistance (LOR) as the epidural needle tip moves from the dense ligamentum flavum to the high-compliance epidural space. Performing the LOR technique using the EpiFaith® syringe, the piston within the syringe moves forward driven by spring force when a drop in pressure is detected. Piston movement within the syringe is visibly detectable with a yellow indicator in the syringe when LOR occurs. In a feasibility study of 40 labor epidural placements, 3 of 4 expert obstetric anesthesiology physicians reported the EpiFaith® syringe to be equal to superior in quality to the standard LOR syringe, with 100% success rate and no inadvertent dural punctures (3). Evaluating the impact of the EpiFaith® syringe on learning curves of anesthesia residents with minimal prior technical experience will help inform how we approach education regarding the labor epidural technique. Steeper learning curves with faster time to proficiency may benefit both patients and supervising staff, while if no difference is determined, the use of the EpiFaith® syringe can be de-emphasized during the training period.

Notice

Study information shown on this site is derived from ClinicalTrials.gov (a public registry operated by the National Institutes of Health). The listing of studies provided is not certain to be all studies for which you might be eligible. Furthermore, study eligibility requirements can be difficult to understand and may change over time, so it is wise to speak with your medical care provider and individual research study teams when making decisions related to participation.